IMA激光荧光显微高光谱成像系统

IMA激光荧光显微高光谱成像系统

发布时间:2019/11/28 8:12:49

  • 型号: Hyperspectral imaging system
  • 价格: 电议
  • 产地:
  • 采购度: 2397
产品介绍:基于独特的体布拉格光栅滤波片技术(BTF)和光致发光成像技术,Photon etc公司新推出的IMA激光荧光显微高光谱成像系统,采取革新的二维成像的方式,激光经过扩束后再经过匀化,将高斯分布的点激光扩展成平面均匀分布面激光,面激光均匀照射在样品上,可以直接获得整个样品的荧光高光谱信息。
分享到:
产品详情

IMA激光荧光显微高光谱成像系统

 

IMA荧光(EL/PL)显微高光谱成像仪

 

高速读取荧光高光谱

均化激光不会损伤细胞等样品

非逐点扫描

高速PL/EL Mapping

 产品简介

基于独特的体布拉格光栅滤波片技术(BTF)和光致发光成像技术,Photon etc公司新推出的IMA激光荧光显微高光谱成像系统,采取革新的二维成像的方式,激光经过扩束后再经过匀化,将高斯分布的点激光扩展成平面均匀分布面激光,面激光均匀照射在样品上,可以直接获得整个样品的荧光高光谱信息。从而获得分子结构方面的信息。有别于传统的激光荧光显微高光谱系统以逐点扫描的方式,而是一次性的获取整个样品的光谱信息,故而只需要更短的成像时间以及具有更高的空间分辨率。

共焦荧光成像系统,共聚焦荧光成像系统,共焦荧光光谱成像系统,共焦荧光成像光谱仪系统,成像光谱仪,激光荧光成像系统, 荧光显微成像系统

 

参数规格

 

VIS

IR

光谱范围

400-1000nm

900-1700nm

光谱分辨率

<2.5nm(小可到0.2nm)

<4nm(小可到0.4nm

图像分辨率

亚微米

亚微米

成像速度

20x20μm in 1s @100X

20x20μm in 1s @100X

激发光源

447 nm, 532, 635 nm(可选其他波长)

808980nm(可选其他波长)

CCD

科学CCD,背照式CCDEMCCD

InGaAs相机

显微镜

倒置或正置

倒置或正置

物镜

20X60X100X

20X60X100X

 

应用域

NANOPARTICLES IN CANCER CELLS

Dark field illumination is commonly used for the analysis of biological samples containing nanomaterials that significantly scatter light. When combined to hyperspectral imaging, it becomes an exceptional tool to also detect the composition and the location of nanomaterials embedded in cells. IMATM, Photon etc.’s hyperspectral imager, can be equipped with a highly efficient dark field condenser and generate high contrast images of biological samples.

 

The high throughput of Photon etc.’s hyperspectral filter allows the rapid acquisition of spectrally resolved high resolution images. Since the camera captures the whole area in the field of view, it is possible to collect spectral and spatial information in real time, with the possibility of recording spectrally resolved videos to follow the dynamics of cells and luminescent nanoscale components. PHySpecTM, Photon etc software, enables principal component analysis (PCA) in order to identify the smallest variations of single and aggregated nanoparticles.

 

With the purpose of showing the capabilities of IMATM to analyse nanomaterials in biological systems, a sample of MDA-MB-23 human breast cancer cells has been tagged with 60 nm gold nanoparticles (GNPs) and exposed to a dark field illumination on the entire field of view (Figure 1). With a 60×objective, an area of 150×112 μm was imaged, with a step of 2 nm and an exposition time of 2 s per wavelength. The complete analysis took only a few minutes, for more than one million spectra, each of them covering the whole visible spectrum.

 

Cells typically have a flat scattering spectrum, whereas GNPs show a sharp peak around 550 nm. Figure 2 illustrates the 550 nm image extracted from the dark field hyperspectral cube of the breast cancer. The GNPs are marked with a green colouring after PCA software processing. The magnification of a breast cancer cell (Figure 3a) and the spectra of the regions containing GNPs (some examples in Figure 3b) confirmed the presence of single 60 nm NPs (peak at 550 nm) and their aggregates (peaks red-shifted). The hyperspectral camera did not detect any GNPs in the areas between the cells.

 

CHARACTERISATION OF SOLAR CELLS USING HYPERSPECTRAL IMAGER

 

A new characterization method based on hyperspectral imaging recording spectrally resolved images allows the cartography of electroluminescence (EL) and photoluminescence (PL). From the data acquired, spatial variations of cell properties such as open circuit voltage and transport mechanisms were identified and characterized. Furthermore, the system was compared to a classical confocal microscope, showing significant gains in acquisition time.

 

Spectrally resolved images provide considerable advantages such as, absolute calibration of intensity, micrometer scale resolution, and excitation and detection on a surface (no information loss from lateral diffusion and roughness). In luminescence imaging, absolute calibration is a main concern and is here done in two steps: first, an absolute calibration at a determined point (spatially and spectrally) with a laser, and then a relative calibration on the whole space and the whole spectrum, with a calibrated lamp coupled to an integrating sphere.The images rendered by IMATM are spectrally resolved luminescence images from multicrystalline CIS solar cell, offering means of studying its spatial inhomogeneities. On high efficiency GaAs solar cells, we got absolute measurements of EL and successfully investigated reciprocity relations. Our next step is to record quantitative maps of CIGS physical properties from PL and EL images, such as VOC , transport parameters and more.

 

A confocal microscope coupled to a spectrometer provides similar data. The 532nm laser is focused onto the cell front contact, and the cartography of PL spectra is obtained by scanning the sample. The acquisition time with the imager is much faster. 150*150μm2 at 107 W/m2 would take hundreds of hours in confocal, but only 8min with IMA. Moreover, surface excitation and detection allow to get rid of diffusion and roughness troubles for quantitative analysis.

 

MULTIPLEXING OF 17 SWCNTs

NIR hyperspectral microscopy covers the detection range of 900-1700 nm and is ideal for the spatial and spectral identification and measurement of fluorophores that emit in the second biological window. For example, single wall nanotubes (SWNTs) emission bands are narrow (~ 20 nm) and each band corresponds to unique (n, m) species (chiralities). With IR hyperspectral microscopy, it is possible to separate these species, with single SWNT spatial resolution on surfaces, in live cells, and in vivo.


Images obtained by IR hyperspectral microscopy can be used to study fluorescence and spectral heterogeneity from single SWNTs in complex environments, including live cells and tissues.



Locate and identify single SWNTs chiralities

 Identify SWNTs by their IR spectra

 Separate single SWNT (emission band ~ 20 nm)

 Simultaneous imaging of all emitters

 Multiplexing with one laser source

 

Access to second biological window

Attenuated tissue absorbance

 Higher depth of penetration

Less scattering

Limited autofluorescence

 

Monitor spectral information

Changes in intensity of single emitters

Shifts in wavelength

Spectral bandwidth variations 

 

In vivo applications

In vivo imaging of multiplexed emitters

In vivo long term sensing

 

 


 

更新时间:2023/11/11 17:14:01

在线留言

在线咨询,尊敬的客户您好,我们会尽快回复您的咨询!

  • 您感兴趣的产品:

  • 您的单位:

  • 您的姓名:

  • 联系电话:

  • 常用邮箱:

  • 详细地址:

  • 留言内容:

  • 验证码:

温馨提示

1.遵守中华人民共和国有关法律、法规,尊重网上道德,承担一切因您的行为而直接或间接引起的法律责任。

2.请您真实的反映产品的情况,不要捏造、诬蔑、造谣。如对产品有任何疑问,也可以留言咨询。

3.未经本站同意,任何人不得利用本留言簿发布个人或团体的具有广告性质的信息或类似言论。

相关文章
相关产品
产品分类

Product classification

联系人:马经理服务热线:021-51083793地址:上海 上海市虹梅路2007号6号楼3楼

主营产品:昊量代理的产品包括各类激光器、光电调制器、光学测量设备、精密光学元件,连续激光器(CW),ns | ps | fs 脉冲激光器,可调谐激光器,激光量测设备,调制器,偏转器,滤波器,空间光调制产品,信号处理,分析设备,光谱仪器,相机系列,光学器件,光栅,光学晶体,光纤器件,位移台,偏转镜,旋转台,冷原子,量子光学产品,材料分析设备,光学检测设备,显微成像系统及组件,光学隔振平台,THz产品,X射线产品,等

版权所有©上海昊量光电设备有限公司, All Right Reseverd ICP备案号: 沪ICP备08102787号-5 总访问量:492129 管理登录 阿仪网设计制作,未经允许翻录必究

4

阿仪网推荐收藏该企业网站